dc.contributor.author | Yassin, Mohammad | - |
dc.contributor.author | Mahmoud, Nidal | - |
dc.contributor.author | Ghebremichael, Kebreab | - |
dc.contributor.author | Petrusevski, Branislav | - |
dc.date.accessioned | 2018-03-07T09:55:01Z | - |
dc.date.available | 2018-03-07T09:55:01Z | - |
dc.date.issued | 2017-06 | - |
dc.identifier.citation | Yassin M., Mahmoud N., Ghebremichael K., Petrusevski B., 2017. Assessment of a roughing filtration as a pre- treatment for slow sand filtration of canal water with highly variable feed water turbidity. Water Treatment and Desalination, 79, 221-227. | en_US |
dc.identifier.uri | http://hdl.handle.net/20.500.11889/5385 | - |
dc.description.abstract | The slow sand filtration plant (SSF) that produce drinking water for the refugee camp at Aqbat Jaber in Jericho (Palestine) is taken out of operation frequently during the rainy season due to the excessively high feed water turbidity. To allow continuous operation of SSF, the suitability of a pre-treatment process based on 4 layer upflow roughing filters (RFs), with optional coagulation using ferric chloride, was assessed at filtration rates of 0.5 and 1.5 m/h. The RFs without coagulant addition, at both filtration rates, effectively reduced turbidity of feed water from about 90 NTU to <20 NTU. Lower filtration rate resulted in lower filtrate turbidity. The major turbidity removal was attained in the bottom 20 cm layer of the filter column. Very high turbidity of feed water (800–1000 NTU) could be reduced to values acceptable for SSF (<20 NTU) with coagulation supported RF (Fe3+ dosage 9 mg/L ) that operated at filtration rate of 0.5 m/h. | en_US |
dc.language.iso | en | en_US |
dc.publisher | Desalination Publications | en_US |
dc.subject | Water - Purification - Filtration | en_US |
dc.subject | Pre-treatment Water quality | en_US |
dc.subject | Organic water pollutants | en_US |
dc.subject | High turbidity | en_US |
dc.subject | Water - Purification - Coagulation | en_US |
dc.title | Assessment of a roughing filtration as a pre-treatment for slow sand filtration | en_US |
dc.type | Article | en_US |
newfileds.department | Institute of Environmental and Water Studies | en_US |
newfileds.item-access-type | archive | en_US |
newfileds.thesis-prog | Water and Environmental Engineering | en_US |
newfileds.general-subject | none | en_US |
item.fulltext | With Fulltext | - |
item.languageiso639-1 | other | - |
item.grantfulltext | restricted | - |
Appears in Collections: | Fulltext Publications (BZU Community) |
Files in This Item:
File | Description | Size | Format | Existing users please Login |
---|---|---|---|---|
79_2017_221.pdf | 42.47 kB | Adobe PDF | Request a copy |
Page view(s)
104
Last Week
0
0
Last month
3
3
checked on Mar 25, 2024
Download(s)
17
checked on Mar 25, 2024
Google ScholarTM
Check
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.